title: "Lab results in plain language: what cut support calls by 24%"
author: "Mykyta Syvash"
date: "2026-11-13"
lang: "en"
url: "https://mykytasyvash.art/writing/lab-results-in-plain-language"
tags:
  - "health-tech"
  - "patient apps"
  - "UX writing"
  - "Smart Lab"
---

# Lab results in plain language: what cut support calls by 24%

> At Smart Lab, patients phoned the contact centre to decode their own results. Reference ranges, out-of-range flags and history did most of the work. The medical accuracy was the hard part.

## In short

- Smart Lab is Ukraine’s leading medical-lab network: 200,000+ patients across 40 branches. I designed the patient web portal and the iOS and Android apps, 2022 to 2024.
- Results used to be a table of values and codes written for clinicians. Patients called to ask one question: is this bad?
- Each result now shows its value, the lab’s own reference range, an out-of-range flag and the history. Result-related calls to the contact centre fell by 24%.
- Three rounds of usability testing with real patients, and prototypes that won over a sceptical senior team.

The brief at Smart Lab was never "redesign the results page". It was a cost line. The contact centre was taking a steady stream of calls from patients who had received their results and did not know what they meant. The lab was paying people to read numbers out loud and say, in effect, "ask your doctor". Nobody was happy about it, least of all the patients.

I listened to a sample of those calls before I opened a design file. They were not about the medicine. They were about one question, asked a hundred ways: is this bad?

## What were patients actually looking at?

A results page written for clinicians. A table: the analyte, a value, a unit, sometimes a reference interval in a smaller column, sometimes not, and the abbreviations a doctor would recognise and a patient would not. No indication of which values mattered. No comparison with last time. A long list where the one line that worried you sat between forty lines that did not.

Doctors read that table in seconds because they know what to skip. Patients read every line, and then they call.

## What a result needs to say

The redesign comes down to four things each result has to answer, in order.

The value, in the unit the lab uses, with the name written out. "Haemoglobin, 118 g/L" instead of a code.

Whether it is inside the range the lab considers normal for this test, with the range shown. Not a generic range from a textbook: this lab's, for this method, for this patient's sex and age where the lab differentiates. That detail is where medical accuracy lives, and it was the longest conversation I had with the lab's clinicians.

A flag when it is outside the range. Visually quiet but unmissable: the out-of-range results come first, and the rest of the list stays calm. This is the part that answers "is this bad" without the app pretending to be a doctor. It says "outside the reference range", not "abnormal", and never "you have".

The history. The same test from the last visit, and the one before, as a small series. A value that is outside the range but moving towards it is a different story from one moving away, and the series tells that story without a sentence.

## Why plain language is a medical-accuracy problem

The temptation with plain language is to explain. "Low haemoglobin can mean anaemia." We did not do that, and it was the right call. The lab is not the patient's doctor; an explanation on the screen becomes a diagnosis in the patient's head, and a wrong one is worse than a confusing number. The explanation stayed with the physician.

What we did instead was make the structure explain. Range, flag, history: a patient who sees "outside the range, and higher than last time" knows to make the appointment. A patient who sees "inside the range, like last time" stops calling. Both are true, and neither pretends to interpret.

My own medical training mattered here mostly as a brake. I knew which shortcuts would be wrong, and I could argue with the clinicians in their language when a plain-language label risked saying too much.

## How we tested it

Three rounds with real patients, on interactive prototypes, before a line of code. The senior team was sceptical at first, understandably: the results page is the most regulated screen in the product. Watching patients find their flagged value in under ten seconds, on a prototype, in the lab's own waiting room, did more than any deck. Each round moved something: the first killed the colour coding we had been proud of, because red read as "danger" even when the deviation was trivial. The second settled where the range goes. The third was mostly about the history view on a phone.

## What the number means

Result-related calls to the contact centre fell by 24 percent. Not all calls, that figure would be meaningless, since people call to book and to ask about prices. Calls whose reason was "what does my result mean". That category is the one the design touched, so that is the one we measured.

The same work carried into the rest of the product: the plain-language structure became the first component set of the lab's design system across web, iOS and Android, which is its own story. But the thing I keep from Smart Lab is simpler. When the structure of the information matches the question in the user's head, the support ticket does not get written.

## Related

- [Smart Lab case study](https://mykytasyvash.art/smartlab-case/index.html)
- [Patients search by symptom, not by test name](https://mykytasyvash.art/writing/search-by-symptom)

---

By [Mykyta Syvash](https://mykytasyvash.art), November 2026. More essays: [https://mykytasyvash.art/writing](https://mykytasyvash.art/writing).